Fault-tolerant current and reactive power predictive control in a multi-modular 2-level indirect matrix converter

Thumbnail
Artículo de conferencia de suscripción (933.4Kb)
Exportar
RISMendeleyRefworksZotero
Compartir
URI
http://hdl.handle.net/20.500.14066/4585
Registro completo
Mostrar el registro completo del ítem
Autor(es)
Palacios Pereira, Fabian; Toledo Gallardo, Sergio RamónAutoridad CONACYT; Maqueda Acuña, Edgar MarcialAutoridad CONACYT; Caballero Morilla, David DomingoAutoridad CONACYT; Rivera Abarca, Marco Esteban; Rodas Benítez, Jorge EstebanAutoridad CONACYT; Gregor Recalde, Raúl IgmarAutoridad CONACYT
Fecha de publicación
2025-03-10
Tipo de publicación
info:eu-repo/semantics/conferencePaper
Materia(s)
Indirect matrix converter
Model predictive control
Multi-modular matrix converter
 
Resumen
This paper studied the design of a predictive current control strategy with fault tolerance and reactive power minimization applied to a multi-modular topology based on indirect 2-level matrix converters fed by a six-phase generator. The control algorithm of the proposed strategy involves coupled current signals to perform error compensation between the converter modules, aiming to address potential system faults while maintaining reactive power close to zero. The results, obtained through simulation, were evaluated considering each module’s input and output currents and the final load current, as well as reactive power minimization, incorporating the obtained values of total harmonic distortion and mean squared error. The behaviour was analyzed in steady-state and transient conditions, with the system operating nominally and under fault conditions. The results demonstrate the effectiveness and good performance of the proposed strategy with the utilized topology, achieving a satisfactory response to faults through compensation and constant reactive power minimization.
Colecciones
  • Artículos científicos

Listar

Todo RI-CONACYTComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasPerfil de autorEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

Acceder

Estadísticas

Ver Estadísticas de uso

Consejo Nacional de Ciencia y Tecnología (CONACYT)

Dr. Justo Prieto N 223 entre Teófilo del Puerto y Nicolás Billof, Villa Aurelia.

Telefax: +(595-21) 506 223 / 506 331 / 506 369

Código Postal 001417 - Villa Aurelia

Asunción - Paraguay